Air Conditioner Size Calculator

Find the right Korean AC "pyeong class" and cooling capacity (kW) for a room, an apartment living room or a shop.

ใŽก

Floor area of the room. To cool several rooms with one unit, add their areas.

ppl

Two people are included; each extra person adds about 120 W.

Direction of the main windows
Ceiling height
Conditions

Result

Enter an area to see the result.

Cooling area and capacity by class

ClassTypeCooling areaCapacity
6 pyWall19.8ใŽก2.4 kW
7 pyWall23.1ใŽก2.8 kW
9 pyWall29.8ใŽก3.7 kW
10 pyWall33.1ใŽก4.1 kW
11 pyWall36.4ใŽก4.5 kW
13 pyWall43.0ใŽก5.3 kW
16 pyWall52.9ใŽก6.5 kW
15 pyFloor49.6ใŽก6.1 kW
17 pyFloor56.2ใŽก6.9 kW
18 pyFloor59.5ใŽก7.3 kW
20 pyFloor66.1ใŽก8.1 kW
23 pyFloor76.0ใŽก9.4 kW
25 pyFloor82.6ใŽก10.2 kW
30 pyFloor99.2ใŽก12.2 kW
36 pyFloor119.0ใŽก14.6 kW
40 pyFloor132.2ใŽก16.3 kW

Basis: product class = cooling area รท 3.3ใŽก; capacity โ‰ˆ cooling area ร— 123 W (spec sheets: 6-pyeong 18.7ใŽก / 2.3 kW, 17-pyeong 56.9ใŽก / 7.0 kW). Living rooms use at least half the supply area; south-facing or enclosed-balcony homes go one class up (LG Electronics buying guide). Direction, floor, insulation, business and occupancy add-ons are rules of thumb, not a full load calculation.

Share this tool

Related Tools

๐ŸงฅOutfit Color Coordinator
๐Ÿ“…30 Day Challenge Tracker
๐Ÿ‹๏ธ1RM & Barbell Plate Calculator
๐Ÿ’งBMI & Health Calculator
๐Ÿ“†D-Day Calculator
๐ŸŽ‚Korean Date Calculator

Air conditioner size calculator: the right class and kW

In Korea air conditioners are sold by "pyeong class", which is simply the cooling area divided by 3.3ใŽก. Spec sheets show a 6-pyeong unit covering about 19ใŽก with roughly 2.3 kW of cooling and a 17-pyeong unit covering about 57ใŽก with 7.0 kW, which works out to about 123 W per square metre. A bedroom or studio therefore needs a class equal to its floor area, but a living-room floor-standing unit is chosen from at least half of the apartment's supply area rather than the apartment class itself: a 34-pyeong apartment (about 112ใŽก supply) needs a 17-pyeong unit, or a 20-pyeong unit if it faces south with an enclosed balcony. This calculator starts from that manufacturer basis and adds south or west windows, large glazing, top-floor heat, old insulation, an open kitchen, high ceilings and extra occupants. It then shows the cooling area, capacity in kW and BTU/h, and the matching wall-mounted (6โ€“16) or floor-standing (15โ€“40) class. Shops such as cafรฉs, restaurants, Korean BBQ, PC cafรฉs and gyms include business heat, and loads above a 40-pyeong class are split across several units. The add-ons are rules of thumb, so commercial installs should still get an on-site load calculation.

Common Use Cases

๐Ÿ›๏ธ
Pick a Wall Unit for a Room
A 33ใŽก (10-pyeong) room needs a 10-pyeong wall unit of about 4.1 kW, and a 20ใŽก studio a 6-pyeong unit โ€” or 7-pyeong if it faces west on the top floor.
๐Ÿ›‹๏ธ
Living-Room Floor Unit
A 24-pyeong apartment needs a 15-pyeong floor unit, a 34-pyeong apartment 17, and a 45-pyeong apartment 23. Use it to choose the floor unit of a two-in-one set.
โ˜•
Cafรฉs and Restaurants
A 66ใŽก cafรฉ with 15 people needs about 89ใŽก of cooling area, a 30-pyeong class of roughly 10.9 kW, rising to a 36-pyeong class with a 3.3 m exposed ceiling.
๐Ÿ“‹
Check Quotes in kW
Compare installer quotes or rated capacity on spec sheets. A 66ใŽก BBQ restaurant with 30 people and a 3 m ceiling needs about 18 kW, for example two 23-pyeong units.

How to Use

  1. 1
    Choose the Space
    Use Room for bedrooms and studios, Apartment living for a floor-standing living-room unit, and Shop / office for spaces with many people or appliances.
  2. 2
    Enter the Area
    Type the floor area in ใŽก or pyeong, or the apartment class for a living room; half of its supply area becomes the cooling area.
  3. 3
    Set the Conditions
    Choose window direction, large windows, top floor, old insulation, ceiling height and usual occupants. For shops, pick the business type.
  4. 4
    Read the Result
    See the recommended class and unit type, cooling area, capacity in kW, and each add-on, then compare with spec sheets in the table.

Frequently Asked Questions