Find the right Korean AC "pyeong class" and cooling capacity (kW) for a room, an apartment living room or a shop.
ใก
Floor area of the room. To cool several rooms with one unit, add their areas.
ppl
Two people are included; each extra person adds about 120 W.
Direction of the main windows
Ceiling height
Conditions
Result
Enter an area to see the result.
Cooling area and capacity by class
Class
Type
Cooling area
Capacity
6 py
Wall
19.8ใก
2.4 kW
7 py
Wall
23.1ใก
2.8 kW
9 py
Wall
29.8ใก
3.7 kW
10 py
Wall
33.1ใก
4.1 kW
11 py
Wall
36.4ใก
4.5 kW
13 py
Wall
43.0ใก
5.3 kW
16 py
Wall
52.9ใก
6.5 kW
15 py
Floor
49.6ใก
6.1 kW
17 py
Floor
56.2ใก
6.9 kW
18 py
Floor
59.5ใก
7.3 kW
20 py
Floor
66.1ใก
8.1 kW
23 py
Floor
76.0ใก
9.4 kW
25 py
Floor
82.6ใก
10.2 kW
30 py
Floor
99.2ใก
12.2 kW
36 py
Floor
119.0ใก
14.6 kW
40 py
Floor
132.2ใก
16.3 kW
Basis: product class = cooling area รท 3.3ใก; capacity โ cooling area ร 123 W (spec sheets: 6-pyeong 18.7ใก / 2.3 kW, 17-pyeong 56.9ใก / 7.0 kW). Living rooms use at least half the supply area; south-facing or enclosed-balcony homes go one class up (LG Electronics buying guide). Direction, floor, insulation, business and occupancy add-ons are rules of thumb, not a full load calculation.
Air conditioner size calculator: the right class and kW
In Korea air conditioners are sold by "pyeong class", which is simply the cooling area divided by 3.3ใก. Spec sheets show a 6-pyeong unit covering about 19ใก with roughly 2.3 kW of cooling and a 17-pyeong unit covering about 57ใก with 7.0 kW, which works out to about 123 W per square metre. A bedroom or studio therefore needs a class equal to its floor area, but a living-room floor-standing unit is chosen from at least half of the apartment's supply area rather than the apartment class itself: a 34-pyeong apartment (about 112ใก supply) needs a 17-pyeong unit, or a 20-pyeong unit if it faces south with an enclosed balcony. This calculator starts from that manufacturer basis and adds south or west windows, large glazing, top-floor heat, old insulation, an open kitchen, high ceilings and extra occupants. It then shows the cooling area, capacity in kW and BTU/h, and the matching wall-mounted (6โ16) or floor-standing (15โ40) class. Shops such as cafรฉs, restaurants, Korean BBQ, PC cafรฉs and gyms include business heat, and loads above a 40-pyeong class are split across several units. The add-ons are rules of thumb, so commercial installs should still get an on-site load calculation.
Common Use Cases
๐๏ธ
Pick a Wall Unit for a Room
A 33ใก (10-pyeong) room needs a 10-pyeong wall unit of about 4.1 kW, and a 20ใก studio a 6-pyeong unit โ or 7-pyeong if it faces west on the top floor.
๐๏ธ
Living-Room Floor Unit
A 24-pyeong apartment needs a 15-pyeong floor unit, a 34-pyeong apartment 17, and a 45-pyeong apartment 23. Use it to choose the floor unit of a two-in-one set.
โ
Cafรฉs and Restaurants
A 66ใก cafรฉ with 15 people needs about 89ใก of cooling area, a 30-pyeong class of roughly 10.9 kW, rising to a 36-pyeong class with a 3.3 m exposed ceiling.
๐
Check Quotes in kW
Compare installer quotes or rated capacity on spec sheets. A 66ใก BBQ restaurant with 30 people and a 3 m ceiling needs about 18 kW, for example two 23-pyeong units.
How to Use
1
Choose the Space
Use Room for bedrooms and studios, Apartment living for a floor-standing living-room unit, and Shop / office for spaces with many people or appliances.
2
Enter the Area
Type the floor area in ใก or pyeong, or the apartment class for a living room; half of its supply area becomes the cooling area.
3
Set the Conditions
Choose window direction, large windows, top floor, old insulation, ceiling height and usual occupants. For shops, pick the business type.
4
Read the Result
See the recommended class and unit type, cooling area, capacity in kW, and each add-on, then compare with spec sheets in the table.
Frequently Asked Questions
A. No. The class is the area one unit can cool, and a living-room floor unit usually covers just the living room and kitchen. Manufacturers advise at least half the supply area, so a 34-pyeong apartment needs a 17-pyeong unit, or 18โ20 if it faces south with an enclosed balcony. Bedrooms get separate 6โ7-pyeong wall units.
A. Comparing cooling area and rated capacity on spec sheets gives about 123 W per square metre: a 6-pyeong unit is about 2.4 kW, 10-pyeong about 4.1 kW, 17-pyeong about 6.9 kW and 30-pyeong about 12.2 kW. Models vary slightly, so compare the kW printed on the spec sheet.
A. An oversized unit reaches the set temperature quickly and cycles on and off, removing less humidity and costing more to buy. Modern inverter units can run slowly, so one class up is fine, but going two or three classes larger is not recommended. If the result falls between two classes, take the larger one.
A. The class, area and kW relationship and the living-room rule follow manufacturer spec sheets and LG Electronics' buying guide. The other add-ons, such as +10% for west windows or the top floor and business heat, are common installer rules of thumb. Large shops should get an on-site survey and load calculation.